| ===== Dry Spouts ===== | ===== Dry Spouts ===== | ||
| + | |||
| + | Dry spouts do not have a water cooling system. | ||
| + | |||
| + | ====== Emergencies ====== | ||
| + | |||
| + | ===== Smelt Spout Jacket Water Leak ===== | ||
| + | |||
| + | If you have a **confirmed smelt spout cooling water leak** through the spout water jacket, it is necessary to shut off the cooling water to this spout. Once done, there is a decision to be made: | ||
| + | |||
| + | * **Continue Running** | ||
| + | {{ boiler: | ||
| + | If you can run the recovery boiler without this spout, then plug the spout according to the manufacturer' | ||
| + | |||
| + | * **Shutdown the Boiler** | ||
| + | |||
| + | If you cannot continue running with the plugged spout, shut the boiler down orderly, burning out the bed, and replace the smelt spout. | ||
| + | |||